Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Argent Microbiol ; 46(3): 196-200, 2014.
Artigo em Espanhol | MEDLINE | ID: mdl-25444127

RESUMO

The introduction of nucleic acid amplification techniques (NAT) in blood banks was intended to reduce the residual risk of transfusion-transmitted infections. Co-circulation of a great diversity of HIV-1 variants in Argentina portrays the need to assess the sensitivity of serological and molecular assays available for their detection. In this study, we evaluated the sensitivity of the COBAS AmpliScreen™ HIV-1 Test, version 1.5 (Roche) for the detection of HIV-1 RNA in plasma samples of infected individuals from Argentina. The results of this study reveal that this technique has high sensitivity for the detection of HIV-1 RNA under assay conditions: using mini-pool testing, pools ≥ 50 RNA copies per ml achieved ≥ 92 % sensitivity, whereas in the standard procedure, samples ≥ 207 RNA copies/ml achieved 100 % sensitivity. Moreover, the COBAS AmpliScreen™ HIV-1 Test, version 1.5 (Roche) is suitable for detecting prevailing HIV-1 variants.


Assuntos
Colorimetria/métodos , Infecções por HIV/virologia , HIV-1/isolamento & purificação , RNA Viral/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Viremia/virologia , Argentina/epidemiologia , Segurança do Sangue , Técnicas de Genotipagem , Infecções por HIV/sangue , Infecções por HIV/epidemiologia , HIV-1/classificação , HIV-1/genética , Humanos , Programas de Rastreamento/métodos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Ultracentrifugação , Carga Viral
2.
Rev. argent. microbiol ; 46(3): 196-200, oct. 2014.
Artigo em Espanhol | LILACS | ID: biblio-1008778

RESUMO

Las técnicas de amplificación de ácidos nucleicos (NAT) se incorporaron en los bancos de sangre para reducir el riesgo residual de transmisión de infecciones por vía transfusional. La cocirculación de distintas variantes del HIV-1 en Argentina indica la necesidad de evaluar la sensibilidad de los ensayos serológicos y moleculares disponibles para su detección. En este trabajo se evaluó la sensibilidad del equipo COBAS AmpliScreenTM HIV-1 Test, versión 1.5 (Roche), para detectar ARN viral en plasmas de individuos infectados con HIV-1 de Argentina. Los resultados demuestran que esta técnica tiene una alta sensibilidad para detectar ARN de HIV-1 en las condiciones ensayadas: para ensayo de mini-pooles (pooles ≥ 50 copias de ARN/ml), la sensibilidad fue ≥ 92 %, y para procedimiento estándar (plasmas ≥ 207 copias de ARN/ml), la sensibilidad fue 100 %. Además, la técnica COBAS AmpliScreenTM HIV-1 Test, versión 1.5 (Roche), es adecuada para la detección de las variantes de HIV-1 prevalentes


The introduction of nucleic acid amplification techniques (NAT) in blood banks was intended to reduce the residual risk of transfusion-transmitted infections. Co-circulation of a great diversity of HIV-1 variants in Argentina portrays the need to assess the sensitivity of serological and molecular assays available for their detection. In this study, we evaluated the sensitivity of the COBAS AmpliScreenTM HIV-1 Test, version 1.5 (Roche) for the detection of HIV-1 RNA in plasma samples of infected individuals from Argentina. The results of this study reveal that this technique has high sensitivity for the detection of HIV-1 RNA under assay conditions: using mini-pool testing, pools ≥ 50 RNA copies per ml achieved ≥ 92 % sensitivity, whereas in the standard procedure, samples ≥ 207 RNA copies/ ml achieved 100 % sensitivity. Moreover, the COBAS AmpliScreenTM HIV-1 Test, version 1.5 (Roche) is suitable for detecting prevailing HIV-1 variants


Assuntos
Humanos , HIV-1/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Infecções por HIV/sangue
3.
Rev. Argent. Microbiol. ; 46(3): 196-200, 2014 Jul-Sep.
Artigo em Espanhol | BINACIS | ID: bin-133302

RESUMO

The introduction of nucleic acid amplification techniques (NAT) in blood banks was intended to reduce the residual risk of transfusion-transmitted infections. Co-circulation of a great diversity of HIV-1 variants in Argentina portrays the need to assess the sensitivity of serological and molecular assays available for their detection. In this study, we evaluated the sensitivity of the COBAS AmpliScreen HIV-1 Test, version 1.5 (Roche) for the detection of HIV-1 RNA in plasma samples of infected individuals from Argentina. The results of this study reveal that this technique has high sensitivity for the detection of HIV-1 RNA under assay conditions: using mini-pool testing, pools  50 RNA copies per ml achieved  92


sensitivity, whereas in the standard procedure, samples  207 RNA copies/ml achieved 100


sensitivity. Moreover, the COBAS AmpliScreenÔäó HIV-1 Test, version 1.5 (Roche) is suitable for detecting prevailing HIV-1 variants.


Assuntos
Colorimetria/métodos , Infecções por HIV/virologia , HIV-1/isolamento & purificação , RNA Viral/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Viremia/virologia , Argentina/epidemiologia , Segurança do Sangue , Técnicas de Genotipagem , Infecções por HIV/sangue , Infecções por HIV/epidemiologia , HIV-1/classificação , HIV-1/genética , Humanos , Programas de Rastreamento/métodos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Ultracentrifugação , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...